Leda Glazed Door, Industrial Panel Lift Doors, Docks Doors, Australia



Send to Friend
Leda glazed door

Leda glazed door

Product Code : LGD

Glazed panel lift doors
Manual or automated
Lift with springs to meet OHS requirements
Security locks
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enlarge
Example specification
Leda glazed door of 2500mm height and 3100mm width of clear opening. Door is to be LPS-200 type lift for low ceiling height. Operation of door to be by automation of 3 phase motor to be supplied with door. Door structure to be anodized aluminium and glazing to be contiuous for span of door. Panel heights to be 610mm and bottom panel to be glazed and not a solid panel.

Installation to enable integration of door with operation of car lifting device.

Submittals
Product Data: Submit Manufacturer’s product data for all door equipment including:

1. Manufacturer’s standard details and fabrication method.
2. Data on finishing, hardware and accessories.
3. Recommendations for maintenance and cleaning of exterior finish surfaces.

Shop drawings for door and installation are required from manufacturer, including:

1. Layout and installation details.
2. securing to wall details.
3. Wiring diagrams
.
Quality Assurance
Installer qualifications: Engage an experienced door installer who has completed installations of all equipment similar in design and extent to those required for the project and whose work has resulted in construction with a record of successful in service performance.

Manufacturer’s qualifications: Provide all door produced by a firm experienced in manufacturing door systems that are similar to those indicated for this project and that have a record of successful in service performance. All doors must be tested.

Single source responsibility: Obtain all doors from a single manufacturer, to ensure full compatibility and warranty of parts.

Design criteria: The drawings indicate the size, profile and dimensional requirements of all doors required and are based on the specific types and models indicated. All doors by other manufacturers may be considered, provided deviations in dimensions and profiles are minor and do not change the design concept as judged by the Architect. The burden of proof of equality is on the proposer.

Delivery storage and handling
Deliver all doors and related components in the manufacturer’s original protective packaging. Do not deliver doors until the work is ready for their installation.

Inspect components for damage upon delivery. Unless minor defects in metal components can be made to meet the Architect’s specifications and satisfaction, damaged parts should be removed and replaced.

Project conditions
Field Measurements: Check opening by accurate field measurement before fabrication. Show recorder measurements on shop drawings. Coordinate fabrication schedule with construction progress to avoid delay of the work and possible damage to the finished product.

Where necessary, proceed with fabrication without measurement and coordinate fabrication tolerances to insure proper fit.

Acceptable Manufacturers
Basis of design: Design is based on door type, manufactured by Leda Security Products Pty Ltd

Subject to compliance with requirements, doors from other manufacturers meeting the specified requirements may be acceptable.

Additional materials
Accessory Fittings: Provide manufacturer’s standard accessory fittings of the type indicated. Comply with requirements indicated for kind and form of metal and finish of door fittings.

Anchors and Fasteners: Manufacturer’s standard anchors and fastenings.

Fabrication
General: Fabricate all door components to designs and sizes indicated. Sizes of door and profile requirements of fittings and hardware are indicated on the drawings.

Prefabrication: Complete fabrication, assembly, finishing, hardware application and other work to the greatest extent possible before shipment to the project site. Disassemble components only as necessary for shipment and installation.

Automation
General: Automation of doors if required will be to required operation standard based on top or mid tier equipment. Top tier relating to automation equipment with the door weight, speed and operation frequency well within specification. Mid tier relating to less stringent or frequent operating environments.

Standards: Equipment is to comply with all relevant and electrical and safety for the legal jurisdiction of installation.

Execution
Examination
Examine footing with the installer, present for compliance with requirements indicated, installation tolerances and other conditions that affect the installation of all doors such as wind loadings.

Correct unsatisfactory conditions before proceeding with the installation.

Do not proceed with installation until unsatisfactory conditions are corrected.

Installation
Install door and associated components in accordance with manufacturer’s printed instructions and recommendations.
1. Verify units level, plumb and true line.
2. Lubricate hardware and other moving parts.

Adjusting
Adjust door to provide a tight fit at meeting points.

Hardware: Adjust operating hardware to ensure proper operation.

Cleaning
Clean door surfaces after installation, exercising care to avoid damage to the finish.

Protection
Institute protective measures required throughout the remainder of the construction period to ensure that the all doors do not incur any damage or deterioration, other than normal weathering, at the time of acceptance.

Warranty
Door and warranty to be not less than 12 months on installation but otherwise as per contract or manufacturers warranty.

Maintenance
Maintenance is to be based on frequency of use and to be as per manufacturers maintenance manuals to be supplied with equipment.

Sizing
Max width 6250mm
Max height 6750mm

Operation
Standard is manual operation with chain
Options
Automation with chain in event of motor or power failure
Automation without chain

Lift options*
NS - standard lift with 420mm head room (Standard door)
NS FTR - standard lift with 420mm head room and angled roof
LPS-200 - Low celing height of 200mm
LPS-200 FTR - Low celing height of 200mm and angled roof
HS - High lift
HS FTR - High lift with angled roof
HS Dock - High lift with springs and motor just above clear opening height
HSK - High lift with springs and motor just above clear opeing height
VS - Vertical lift
VS dock - Vertical lift with springs and motor lust above clear openinhg height.
*see separate document for full lifting profiles

Material

Aluminium profiles

Finish
Aluminium anodized for to 25lm thick oxide layer

Glazing
Standard is SAN Styrene Acrylon Nitrile (thermoplastic)

Glazing options
Acrylic
Saftety glass
Polycarbonate

Other fill options
Aluminium embossed sheet
Perforated aluminium

Bottom panel
Normally recommended as a hard S40 panel for strength of larger doors and is the most damages and wearing panel. Receives rain splatter external door.
Option of bottom panel being completely glazed on request.

Door options
Automation
Spring break safety device
Cable break safety device
Slack cable sefety device
Safety edge
Anti lift device
Finger protection

  File Title
Leda Industrial door brochure Leda Industrial door brochure (1.19 MB)
Leda glazed door Door sizing and lifting options (2.03 MB)
 
No videos for this product.